Genie 3511035556 SECT 4-WALL CONTROL INSTALLATION, 1/2 1-1/4” to 1-1/2, Mount wall control. Fig

Models: 3511035556

1 35
Download 35 pages 34.29 Kb
Page 24
Image 24
SECT 4—WALL CONTROL INSTALLATION

SECT 4—WALL CONTROL INSTALLATION

FOR HELP- 1.800.354.3643

24

WARNING

Power must be removed before attaching wires. Be sure ends do not touch each other or other terminals.

CAUTION

Use of any other wall control can cause the door to operate unexpectedly and the light not to work.

Cut or pinched wires can cause door operator to malfunction. Drive staples just tight enough to hold wire.

1.Run wire from power head to wall control

Find location for wall control:

In sight of door and away from moving parts.

At least 5 feet from floor, so small children cannot reach it.

Route wire from wall control to power head.

Use staples to fasten wire to ceiling and wall.

NOTE: Use only staples included

2.Split wires at ends and remove 1/2 inch of insulation from end of each Wire. Fig. 4-1.

3.Attach wires to terminals. Fig. 4-2, Fig. 4-3.

Loosen (Do Not Remove) screws from Terminals at power head and wall control

Connect wires to power head

White wire to terminal # 1

Striped wire to terminal #2

Tighten screws

Connect wires to wall control

Striped wire to terminal “B”

White wire to terminal “W”

Tighten screws

4.Mount wall control. Fig. 4-4.

For Wall Console or Wall Button.

Use pan head screws [34].

5.Mount entrapment warning label. Fig. 4-4.

Remove protective backing.

Stick label to wall next to wall control.

Tacks or staples may be required on some rough texture surfaces.

NOTE: Additional wall controls are available from your dealer. ONLY ONE OF YOUR WALL CONTROLS MAY BE THE LIGHTED TYPE. If you have a lighted wall control, all your additional controls must be un-lighted. More than one lighted wall control per operator will cause a malfunction.

1/2"

1-1/4” to 1-1/2"

Fig. 4-1

Fig. 4-2

 

 

 

 

 

 

 

button

 

 

console

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 4-3

Fig. 4-4

1.Run wire from power head to wall controlNOTE: Use only staples included [34]

#6 x 1-1/4" Pan head screw

Page 24
Image 24
Genie 3511035556 manual SECT 4-WALL CONTROL INSTALLATION, 1/2 1-1/4” to 1-1/2, Run wire from power head to wall control