Pressure Relief Procedure
Pressure Relief Procedure
Relieve pressure before cleaning or repairing gun.
1. Close both manual valves.
Manual Valves
FIG. 19: Close Manual Valves
2.Set safety stop to OPEN.
3.Trigger gun onto cardboard or into waste container to relieve pressure.
4.Release gun trigger, set safety stop to CLOSED, and close manual valves.
If fluid in hose and proportioner is still under pressure, follow Pressure Relief Procedure in proportioner manual
To relieve pressure in hose after gun is removed, place fluid manifold over contain- ers, facing away from you. Very carefully open fluid valves. Under high pressure, fluid will spray sideways from fluid ports. See FIG. 21.
TI2484a
FIG. 21: Open Manual Valves
2!
FIG. 20: Trigger Gun
311321H | 19 |