Coupling Block
Chemical hoses are joined to gun block by coupling block to ease installation and removal of gun.
Manual Valves
Two manual valves located on coupling block control flow of each chemical component to gun.
Triggering gun with manual valves closed
may cause crossover if any residual chem- ical remains in gun ports.
Never open manual valve unless coupling block is secured to gun or unless you point gun into waste container.
Open Manual Valves
Use 5/16 in. nut driver to turn manual valve counterclockwise three full turns.
Coupling
Block
Manual Valves
FIG. 14: Open Manual Valves
Operation Basics
Close Manual Valves
Use 5/16 in. nut driver to turn manual valve fully clockwise.
CAUTION
To prevent accidental gun operation, always set safety stop to CLOSED (SERVICE), close both manual valves, and disconnect air supply.
Installation and Removal
To prevent release of pressurized chemicals, close both manual valves before removing coupling block.
Install Coupling Block
1.Replace nicked, damaged, or worn cou- pling block gaskets.
2.With gaskets in place, fit coupling block to gun block.
311321H | 13 |