Graco Inc GX-7 400, 311321H, GX-7 DI, GX-7A important safety instructions Flush Gun

Models: GX-7A 311321H GX-7 DI GX-7 400

1 50
Download 50 pages 51.4 Kb
Page 21
Image 21

2.Close both manual valves.

3.Remove gun from coupling block.

4.Attach service block of gun service kit to spray gun, and then tighten using 5/16 in. nut driver.

5.Pressurize Service Kit container up to 100 psi. DO NOT EXCEED 100 psi (0.7 MPa, 7 bar).

6.Open one manual valve on service block.

7.Connect air to gun. Set safety stop to OPEN.

8.Hold gun against grounded waste con- tainer.

9.Trigger gun and 1-Quart Gun Service Kit. Spray into waste container until there is a fine, unobstructed mist of gun cleaner.

10.Release both triggers and close manual valve on service block.

11.Repeat steps 5-7 for other side of gun.

12.After initial cleaning, remove air cap, PCD retainer, and PCD. Flush a second time to ensure thorough cleaning.

13.Remove service block of gun service kit from spray gun.

14.Set safety to CLOSED (SERVICE).

15.Disconnect air supply.

Maintenance

16.Clean screens, check valves and screen screw as required. See Service Screen Screw, page 22.

Inspect air cap, PCD, mixing module, and gun block for build up of material and clean as required.

Do not use metal cleaning devices to clean plastic components.

Flush Gun

To avoid static sparking that may result in fire or explosion, ensure all equipment in flushing procedure is grounded. Do not flush on or near foamed or coated surfaces.

1.Set safety stop to CLOSED (SERVICE).

2.Close both manual valves.

3.Loosen R-Screen screw and then remove by hand.

4.Use flush can to thoroughly flush screen screw and screen screw cavity.

5.Loosen A-Screen screw and then remove by hand.

6.Use flush can to thoroughly flush screen screw and screen screw cavity.

7.Service gun by following Maintenance pro- cedures, page 20.

311321H

21

Page 21
Image 21
Graco Inc GX-7 400, 311321H, GX-7 DI, GX-7A important safety instructions Flush Gun