Warnings

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Do not spray flammable or combustible materials near an open flame or sources of ignition such as cig- arettes, motors, and electrical equipment.

Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity cre- ates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system, including the pump, hose assembly, spray gun, and objects in and around the spray area shall be prop- erly grounded to protect against static discharge and sparks. Use Graco conductive or grounded high-pressure airless paint sprayer hoses.

Do not clean with materials having flash points lower than 70° F (21° C). Use water-based material or mineral spirits-type material only. For complete information about your fluid, request the MSDS from the fluid distributor or retailer.

Verify that all containers and collection systems are grounded to prevent static discharge.

Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter.

Do not use a paint or a solvent containing halogenated hydrocarbons.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. Keep pump assembly in a well ventilated area. Do not spray pump assembly.

Do not smoke in the spray area.

Do not operate light switches, engines, or similar spark producing products in the spray area.

Keep area clean and free of paint or solvent containers, rags, and other flammable materials.

Know the contents of the paints and solvents being sprayed. Read all Material Safety Data Sheets (MSDS) and container labels provided with the paints and solvents. Follow the paint and solvents manu- facturer’s safety instructions.

Fire extinguisher equipment shall be present and working.

Sprayer generates sparks. When flammable liquid is used in or near the sprayer or for flushing or clean- ing, keep sprayer at least 20 feet (6 m) away from explosive vapors.

SKIN INJECTION HAZARD

Do not aim the gun at, or spray any person or animal.

Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.

Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.

Use Graco nozzle tips.

Use caution when cleaning and changing nozzle tips. in the case where the nozzle tip clogs while spray- ing, follow the Pressure Relief Procedure for turning off the unit and relieving the pressure before removing the nozzle tip to clean.

Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off the unit and follow the Pressure Relief Procedure for turning off the unit.

High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, get immediate surgical treatment.

Check hoses and parts for signs of damage. Replace any damaged hoses or parts.

This system is capable of producing 3300 psi. Use Graco replacement parts or accessories that are rated a minimum of 3300 psi.

Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.

Verify that all connections are secure before operating the unit.

Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.

3A0157A