Troubleshooting

TYPE OF PROBLEM

WHAT TO CHECK

 

HOW TO CHECK

 

 

 

 

Sprayer does not run at all

Check to see if control board is over

1.

Make sure motor air intake is not blocked.

 

heating.

 

 

Digital display shows E=10

2.

Make sure fan has not failed.

 

 

 

3.

Make sure control board is properly connected

 

 

 

to back plate and that conductive thermal paste

 

 

 

is used on power components.

Control board status light blinks

 

4.

Replace control board.

10 times repeatedly

 

 

 

 

 

 

5.

Replace motor.

 

 

 

 

Sprayer Will Not Shut Off

1.Perform Pressure Relief Procedure; page 8. Leave prime valve open and power switch OFF.

Troubleshooting Procedure

Plumb pressure gauge into paint hose, plug sprayer in, and turn power switch ON. Does sprayer reach or exceed its maximum pressure?

2.Remove control box cover so the control board status light can be viewed if available.

NO

 

 

Mechanical problem: See the proper

 

 

fluid pump manual for the sprayer for

 

 

 

 

 

 

 

further trouble shooting procedures.

 

 

 

 

YES

Unplug the transducer from control board. Does motor stop running?

NO

Replace the control board.

YES

Bad transducer. Replace and test

with a new one.

18

3A0157A

Page 18
Image 18
Graco Inc 1095 Premium Hi-Boy, 695 Premium Hi-Boy, 795 Premium Hi-Boy, 3A0157A Sprayer Will Not Shut Off, Yes