Graco Inc 1595 Premium Hi-Boy, 695 Premium Hi-Boy Check to see if transducer and control board

Models: 695 Premium Hi-Boy 1595 Premium Hi-Boy 1095 Premium Hi-Boy 3A0157A 795 Premium Hi-Boy

1 44
Download 44 pages 27.7 Kb
Page 14
Image 14

Troubleshooting

TYPE OF PROBLEM

WHAT TO CHECK

 

HOW TO CHECK

 

 

 

 

Sprayer does not run at all

Check transducer or transducer

1.

Set sprayer to OFF and disconnect power to

 

connections (control board is not

 

sprayer.

Digital display shows E=03

 

detecting a pressure signal).

 

 

 

2.

Check transducer and connections to control board.

 

 

 

 

3.

Disconnect transducer from control board socket.

 

 

 

Check to see if transducer and control board

 

 

 

contacts are clean and secure.

Control board status light blinks

 

 

 

 

 

3 times repeatedly

 

4.

Reconnect transducer to control board socket.

 

 

 

Connect power, set sprayer ON and control knob

 

 

 

to 1/2 turn clockwise. If sprayer does not run,

 

 

 

set sprayer to OFF and go to next step.

 

 

5.

Connect a confirmed working transducer to control

 

 

 

board socket.

 

 

6.

Set sprayer ON and control knob to 1/2 turn

 

 

 

clockwise. If sprayer runs, install new transducer.

 

 

 

Replace control board if sprayer does not run.

 

 

7.

Check transducer resistance with ohmmeter (less

 

 

 

than 9k ohm between red and black wires and 3-6k

 

 

 

ohm between green and yellow wires).

 

 

 

 

14

3A0157A

Page 14
Image 14
Graco Inc 1595 Premium Hi-Boy, 695 Premium Hi-Boy, 795 Premium Hi-Boy, 3A0157A Check to see if transducer and control board