Troubleshooting
TYPE OF PROBLEM | WHAT TO CHECK |
| HOW TO CHECK |
|
|
|
|
Sprayer does not run at all | Check transducer or transducer | 1. | Set sprayer to OFF and disconnect power to |
| connections (control board is not |
| sprayer. |
Digital display shows E=03 |
| ||
detecting a pressure signal). |
|
| |
| 2. | Check transducer and connections to control board. | |
|
| ||
|
| 3. | Disconnect transducer from control board socket. |
|
|
| Check to see if transducer and control board |
|
|
| contacts are clean and secure. |
Control board status light blinks |
|
| |
|
|
| |
3 times repeatedly |
| 4. | Reconnect transducer to control board socket. |
|
|
| Connect power, set sprayer ON and control knob |
|
|
| to 1/2 turn clockwise. If sprayer does not run, |
|
|
| set sprayer to OFF and go to next step. |
|
| 5. | Connect a confirmed working transducer to control |
|
|
| board socket. |
|
| 6. | Set sprayer ON and control knob to 1/2 turn |
|
|
| clockwise. If sprayer runs, install new transducer. |
|
|
| Replace control board if sprayer does not run. |
|
| 7. | Check transducer resistance with ohmmeter (less |
|
|
| than 9k ohm between red and black wires and |
|
|
| ohm between green and yellow wires). |
|
|
|
|
14 | 3A0157A |