Graco Inc 1095 Premium Hi-Boy, 3A0157A Electrical, Type of Problem What to Check HOW to Check

Models: 695 Premium Hi-Boy 1595 Premium Hi-Boy 1095 Premium Hi-Boy 3A0157A 795 Premium Hi-Boy

1 44
Download 44 pages 27.7 Kb
Page 13
Image 13

Troubleshooting

Electrical

Symptom: Sprayer does not run or stops running.

Perform Pressure Relief Procedure; page 8.

Plug sprayer into correct voltage, grounded outlet

Set power switch OFF for 30 seconds and then ON again (this ensures sprayer is in normal run mode).

Turn pressure control knob clockwise 1/2 turn

View digital display

To avoid electrical shock or moving parts hazards when covers are removed for troubleshooting, wait 30 sec- onds after unplugging power cord for stored electricity to dissipate. Keep clear of electrical and moving parts during troubleshooting procedures.

If no digital display is available, use control board status light to troubleshoot prob- lems: Turn ON/OFF switch OFF, remove control cover and then turn power back ON. Observe status light. Blinking LED to- tal count equals digital error code i.e., two blinks equals E=02.

TYPE OF PROBLEM

WHAT TO CHECK

 

HOW TO CHECK

 

 

 

 

Sprayer does not run at all

See flow chart, page 19.

 

 

 

 

 

 

Digital display is blank

 

 

 

 

 

 

 

Control board status light never

 

 

 

lights

 

 

 

 

 

 

 

Sprayer does not run at all

Check transducer or transducer

1.

Make sure there is no pressure in the system (see

 

connections

 

Pressure Relief Procedure, page 8). Check fluid

Digital display shows E=02

 

 

 

path for clogs, such as clogged filter.

 

 

 

 

 

2.

Use airless paint spray hose with no metal braid

 

 

 

1/4 in. x 50 ft minimum. Smaller hose or metal braid

 

 

 

hose may result in high-pressure spikes.

 

 

3.

Set sprayer to OFF and disconnect power to

Control board status light blinks

 

 

 

sprayer.

2 times repeatedly

 

 

 

4.

Check transducer and connections to control board.

 

 

 

 

5.

Disconnect transducer from control board socket.

 

 

 

Check that transducer and control board contacts

 

 

 

are clean and secure.

 

 

6.

Reconnect transducer to control board socket.

 

 

 

Connect power, set sprayer ON and control knob

 

 

 

1/2 turn clockwise. If sprayer does not run properly,

 

 

 

set sprayer to OFF and go to next step.

 

 

7.

Install new transducer. Connect power, set sprayer

 

 

 

ON and control knob 1/2 turn clockwise. Replace

 

 

 

control board if sprayer does not run properly.

 

 

 

 

3A0157A

13

Page 13
Image 13
Graco Inc 1095 Premium Hi-Boy, 695 Premium Hi-Boy, 3A0157A Electrical, Type of Problem What to Check HOW to Check