Pressure Relief Procedure

Pressure Relief Procedure

1.Turn power OFF. Wait 7 seconds for power to dissipate.

ti4265a

2.Lock gun trigger safety. Remove guard and SwitchTip.

ti10166ati2769a

3.Turn pressure to lowest setting. Trigger gun to relieve pressure.

-

ti14841a

 

4.Put drain tube in pail. Turn prime valve down to DRAIN position.

ti14842a

ti2595a

8