Accessory Assembly - HEAD-END ASSIST BAR

1.With the Assist Bar (#1) bracket facing inward toward the bed as shown, align the two holes on the bracket with the first and third holes (from the head-end of the bed) of the pre-welded head deck bracket (#2)

2.For the quick release option, insert the Clevis Pin end of the two Lanyard assemblies (3a) from the outside into the assist bar bracket holes. Insert the hair pins on the opposite end of the lanyard assemblies (3b) into the holes of the clevis pins.

3.For a fixed attachment option, insert two cap screws (#4) from the outside into the assist bar bracket holes. Secure the screws by attaching two Thin Nylon Lock Nuts (#5).

Tighten with two 13/16 wrenches.

Order Kit #ZA80300

to safely remove Hair pin clip grasp on circular end and pull.

optIon 1

 

 

Item #

Qty.

Part #

Description

 

 

 

 

 

 

 

 

 

 

 

 

1

1

999-0803-902G

Assist Bar - Head End

 

 

 

 

 

 

 

 

 

 

 

 

2

1

-

Head Deck Rail Bracket

 

 

 

 

(pre-welded on deck)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

not

2

100-4710-003

1.00” Dia. End Caps

 

 

 

 

shown

 

 

 

 

 

 

 

 

 

 

 

Quick Release Option 1 (in Hdw Bag 999-0803-905)

 

 

 

 

 

 

 

 

 

 

 

 

3

2

999-0784-100

Quick Release

 

 

 

 

Lanyard Assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixed Attachment Option 2 (in Hdw Bag 999-0803-905)

 

 

 

 

 

close-up of Hair

 

 

 

 

 

 

 

 

 

4

2

100-5463-004

5/8-11 x 4.50”

 

pin clip (#8)

 

 

Hex Head Cap Screw

 

inserted into

 

 

 

 

 

 

hole in clevis

 

 

 

 

 

 

 

 

 

 

 

 

5/8-11 Thin Nylon

 

 

5

2

100-6763-001

 

pin (#7)

 

 

Lock Nut

 

 

!

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: The mattress support platform should always be placed in the flat position when not attended.

 

 

When assessing the Risk for Entrapment, you need to consider your bed, mattress, head- and footboards,

 

half rails, assist bars, and other accessories as an entire system. All bed systems are evaluated for compliance

 

to the FDA/CDRH “Hospital Bed System Dimensional and Assessment Guidance to Reduce Entrapment” guidelines.

 

A resident/patient’s condition could lead to resident/patient entrapment. It is extremely important to review the resident/

 

patient’s physical and mental condition, and initiate an appropriate individual care plan to address any entrapment risks.

optIon 2

1

4

5 5

Basic American Medical products, a division of GF Health products, Inc. • Matrix II • rev d Manual

p21

Page 24
Image 24