ASSEMBLY OF U-LEVERS TO STD. CASTER CARRIAGE - 999-0807-955G

Detail B Locking caster assembly on right side of Head end

Detail a U-Lever to caster Brackets (typical assembly)

Detail c non-Locking caster assembly on Left side of Foot end

Item #

Qty.

Part #

Description

1

1

999-0807-903G

Foot U-Lever Weldment

 

 

 

 

2

1

999-0807-913G

Head U-Lever Weldment

 

 

 

 

3

4

999-0775-001

Half Moon Cap

 

 

 

 

4

4

999-0779-100

1/2-13NC x 2.50” Long Button Head Cap Screw (T55)

 

 

 

 

5

8

100-8601-001

.516ID x 1.25”OD x .062”Thk. Nylon Washer

 

 

 

 

6

4

100-6750-006

1/2-13 Low Nylon Lock Nut

 

 

 

 

 

Standard Caster Carriage Assembly 999-0807-955G Includes the following parts

7

1

999-0807-905G

Caster Carriage Weldment

 

 

 

 

8

8

999-0775-001

Half Moon Cap (on Locking Carriage)

 

 

 

 

9

2

100-6330-061

3” Twin Non-Locking Caster

 

 

 

 

10

2

100-6330-062

3” Twin Locking Caster

 

 

 

 

11

4

100-6744-001

7/16-14 Nylon Lock Nut

 

 

 

 

12

4

100-4700-017

1.00” x 2.00” Rectangular End Cap

 

 

 

 

13

4

100-4200-004

1.25” Square Plastic Plug

 

 

 

 

14

4

100-4717-002

1.75” x 10-12GA Round End Cap

 

 

 

 

the standard caster carriage (999-0807-955G) should come pre-assembled. callouts for replacing the casters and caps on both the head and foot end (details B & c) have been included for your convenience. to attach or detach the standard caster carriage from the Matrix II u-levers, please follow the instructions below.

1.place the four Half Moon caps (#3) into the bottoms of both u-levers (#1 & #2) and into the four upright mounting brackets on the caster carriage.

2.Locate the four 1/2-13 x 2.50” Button Head cap screws (#4) and, from the outside, insert them in the bottom holes of the u-levers.

3.place a nylon Washer (#5) onto the ends of each of the exposed ends of the cap screws. carefully position the u-lever legs onto the upright brackets so that the nylon washers rest between them. push the cap screws through the holes in the upright brackets.

4.slide the remaining nylon Washers (#5) onto the cap screws and secure using four 1/2-13 nylon Lock nuts (#6). tighten all hardware using a 5/16 crescent/socket wrench and a t55 torx wrench.

Basic American Medical products, a division of GF Health products, Inc. • Matrix II • rev d Manual

p29