Thermador PDR36, PRG48, PRG30, PRG36, PDR30, PDR48 manual Thermador, Element Supervisor Enabled

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 28
Image 28
Element Supervisor Enabled

Thermador®

S, SM, AND SMW Oven Error Code Messages – Updated 02/21/02

Error Code

 

 

 

 

 

 

Displayed

 

Probable Cause

 

Example

 

Corrective Action

F1

 

Element Supervisor Enabled

 

Main power/relay

 

Replace main power/relay board

 

 

 

 

 

 

 

board

 

 

F1, F7

 

Poor Connection Between Display

 

Intermittent Sensor

 

Replace control head kit & main power/relay

 

 

Head And Touch Panel

 

OR Main power/relay

 

board. See note 1.

 

 

 

 

board

 

 

 

 

 

 

 

 

 

F2

 

Oven Temperature Detected Or Door

 

Intermittent Sensor Or

 

Check oven latch switches & door light are

 

 

Light Coming On After 1 Hour Into

 

Main power/relay

 

operating properly. Check oven sensor from

 

 

Self-Clean

 

board

 

molex plug on main power/relay board.

 

 

 

 

 

 

Should read approximately 1050.

F3

 

Open oven sensor

 

Open Sensor Or

 

Check oven sensor from molex plug on main

 

 

 

 

Circuit Wiring

 

power/relay board. Should read approximately

 

 

 

 

 

 

1050 ohms at room temperature. See note 3.

 

 

 

 

 

 

Check and make sure the temperature sensor

 

 

 

 

 

 

plug on the main power/relay board is in place

 

 

 

 

 

 

and not loose.