WTA 35 & WTL 54 Fault Codes & Troubleshooting
|
|
|
|
|
|
| Anti – | Time fault | Control module failed. | Check voltage at and wiring to |
|
| Crease/End | (drying time too |
| module. Turn off dryer, and |
|
| Light flashes | long) |
| replace faulty module. |
|
|
|
| Door lock failed. | Check voltage at and wiring to |
|
|
|
|
| door lock. Turn off dryer, |
|
|
|
|
| measure door lock resistance and |
|
|
|
|
| replace faulty door lock. |
|
|
|
| Moisture sensor(s) | Run moisture sensor conductance |
|
|
|
| failed. | test. Check voltage at and wiring |
|
|
|
|
| to sensors. Turn off dryer and |
|
|
|
|
| replace faulty sensor(s). |
|
|
|
| Water level switch | Check voltage at and wiring to |
|
|
|
| failed (WTL 5400 |
| |
|
|
| only). |
| |
|
|
|
| faulty |
|
|
|
|
| Check voltage at and wiring to |
|
|
|
|
| ||
|
|
| thermostat tripped and |
| |
|
|
| failed to reset. | faulty |
|
|
|
|
| NOTE: |
|
|
|
|
| (WTL 54) or 212°F (WTA 35) |
|
|
|
|
| Have customer upgrade power |
|
|
|
| Supply voltage too low. | system to provide consistent |
|
|
|
|
| voltage to dryer during heating |
|
|
|
|
| (need min. 198V). |
|
| E1 | Pump failed | Pump failed. | Check voltage at and wiring to |
|
|
| (WTL 5400 |
| pump. Turn off dryer, measure |
|
|
| condensation dryer |
| pump resistance (110 – 136 Ω) |
|
|
| only) |
| and replace faulty pump. |
|
| Dryer won’t run | Dryer not turned on. | Turn “on/off” switch on. |
| |
| or indicator lights | No power to dryer | Check customer circuit breaker, |
| |
|
| won’t come on |
| fuse box or power connections. |
|
|
| (no power to | Dryer fuse has blown. | Unscrew holder cap & replace |
|
|
| dryer) |
| fuse (15A, type |
|
|
|
|
|
|
|