Thermador PDR30 manual One of the elements is not, All the elements are not energized, Problem

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 57
Image 57
One of the elements is not

B

Problem

Possible Solutions

 

 

 

One of the elements is not

1.

Check all connections between the relays on the Power Board and the

energized.

2.

elements.

 

Check the relay outputs on the Power Board.

 

 

All the elements are not energized.

1. Check the common L1 red wire on the Power Board relays.

 

2.

Check the safety thermostat connection in series with black L2 wire.

 

3.

Check, if present, the DLB relay connections on the Auxiliary Relay

 

 

Board.

 

4.

Check, if present, the DLB relay outputs. If they are not OK, replace

 

 

the Auxiliary Relay Board.

 

 

 

Display never turns on

1.

Check Power supply connection on the Power Board (P18 for double

 

 

oven, P5 for single oven).

 

2.

Check the P1A cable between Power and Display Board.

 

3.

Disconnected the P1A cable and measure by a meter the voltages on

 

 

the P1A connector on the Power Board.

 

 

a. If they meet the values indicated in the electric schematics then

 

 

replace the Display Board.

 

 

b. If they don’t meet, replace the Power Board.

41

Page 57
Image 57
Thermador PDR30, PRG48 One of the elements is not, All the elements are not energized, Display never turns on, Problem