Thermador PDR48, PRG48, PRG30, PRG36, PDR30 Thermador, Error Code, Light Sequence Code, Description

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 17
Image 17
Thermador®

Thermador®

Thermador

Professional Ranges Models: PDR30/36/48…PRG30/36/48

The control continuously monitors system parameters for control and oven failures and reports a fault code when a system problem is detected. The control utilizes the ovens blue “on light” and oven “heating light” to report a detected fault code. The control will continue to flash the lights in the appropriate sequence as long as the fault exists.

Detection of a fault does not hinder the ability of the control to continue to function if the fault is not critical for the intended operation. For example: If the range door latch is inoperative, the range will continue to cook since the fault would only prevent the range from self-cleaning.

ERROR CODE

LIGHT SEQUENCE CODE

DESCRIPTION

 

 

 

E1

22

EEPROM ERROR

E2

01

CONTROL NOT CALIBRATED

E3

10

SENSOR OPEN

E4

12

SENSOR SHORTED

E5

21

POTENTIONMETER FAILURE

E6

32

OVER TEMPERATURE-COOKING

E7

23

OVER TEMPERATURE-CLEANING

E9

43

NO COOLING FANS

E11

44

DOOR LATCH FAULT

E12

11

EXP. BOARD NOT CONNECTED

E13

13

VCC LIFT OFF ERROR

E14

55

SELECTOR SWITCH ERROR

1

Page 17
Image 17
Thermador PDR48, PRG48, PRG30, PRG36, PDR30, PDR36 manual Thermador, Error Code, Light Sequence Code, Description