WFK 2401 Washer Fault Codes
Fault | Faults | Possible Causes/Notes | Corrective Actions |
Code |
|
|
|
05 | Drum motor | • Motor drive circuit (Triac) has failed. | • Check voltage at motor connectors when motor is energized. If low or |
| erratic | • Drum drive motor has failed. | no voltage, replace faulty control module. |
|
| • Reserving relays have failed. | • Check voltage at motor connectors when motor is energized. If ~240V, |
|
| NOTE: Fault code occurs during test program. | replace faulty drum motor. |
|
|
| • Check voltage at motor connectors when motor is energized. If voltage |
|
|
| doesn’t reverse, replace faulty control module. |
06 | Door open or | • Door isn’t closed properly. | • Close door securely. If door won’t latch, check door latch and door |
| won’t lock | • Door latch is broken. | hinge alignment. |
|
| • Door lock is faulty. | • Replace broken door latch. |
|
| NOTE: Fault code occurs during customer use | • Measure resistance of door lock mechanism (~ 300 – 1350 Ω). Replace |
|
| faulty door lock mechanism. | |
|
| or test program. |
|
08 | Drum motor | • Drum rear bearing has failed. | • Check how drum rotates. If drum wobbles or won’t move, replace faulty |
| won’t run | • Motor drive circuit (Triac) has failed. | rear bearing. |
|
| • Drum drive motor has failed. | • Check voltage at motor connectors when motor is energized. If low or |
|
| • Reserving relays have failed. | no voltage, replace faulty control module. |
|
| NOTE: Fault code occurs during test program. | • Check voltage at motor connectors when motor is energized. If ~ 240V, |
|
|
| replace faulty drum motor. |
|
|
| • Check voltage at motor connectors when motor is energized. If voltage |
|
|
| doesn’t reverse, replace faulty control module. |