Thermador PRG48, PRG30, PRG36, PDR30, PDR36, PDR48 manual Error, Cause, Corrective Action, F153, F155

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 54
Image 54
F153

B

Error

Cause

 

Corrective Action

 

 

 

 

F153

Control calibration values not in

1.

(If possible, re-calibrate.)

 

range.

2.

Check power and Display Board connectors P1B and associated

 

 

 

wiring.

 

Bad Power Board or Display

4.

If OK, replace Power Board.

 

Board.

5.

If fault persists, replace Display Board.

F155

Checksum match error.

1.

If possible, re-write default data to the Display Board eeprom

 

Wrong eeprom data on Display

 

via P7.

 

2.

If not, replace Display Board.

 

Board.

 

 

 

 

 

 

38

Page 54
Image 54