Thermador PRG30, PRG48, PRG36, PDR30, PDR36, PDR48 manual Gaggenau

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 43
Image 43
GAGGENAU

GAGGENAU

Steamer VK 230

8 FUNCTION CODES

Faults at the appliance, a correct or incorrect adjustment as well as the RESET-function are indicated / confirmed by signals or error codes.

Explanations:

OOOFactory- / universal comparison successfully finished

FError during the RESET (internal self test)

F

1

Error when starting an adjustment, e.g. appliance

 

 

has not yet been adjusted by a factory or universal

 

 

comparison

 

 

Or

 

 

After starting the adjustment, the position „steaming“

 

 

has not been chosen within 8 sec.

 

 

Or

 

 

After an adjustment another adjustment is started

F

2

Fault at the water sensor

F

3

Fault at the steam sensor

F4 Fault at the TRIAC or heating element or the water temperature has not increased for min 50°K/90°F

F 5 Water sensor not in right position (Function code

shown only possible during factory or universal comparison!)

F 6

Steam sensor faulty installed (only possible during

 

factory or universal comparison!)

FAC

Factory comparison is running

dEF

Universal comparison is running

 

Blinking heat up symbol

 

Customer Comparison in use

 

Blinking in the display

 

Holyday safety function/after 4 h continuously

 

running Reset: switch off/on appliance

 

Drain symbol

 

Drain valve did not reach end position

 

Drain symbol

 

Drain valve open

 

Limiter symbol

 

Dry run or overheating / above 107 °C/225°F

 

If appliance will be switched off and on F 2 occurs in

 

the display=Appliance /Sensor too hot.

 

Reset: Switch off appliance to cool down

Display compl. Switched ON and sounding signal

Reset confirmation/Display and Buzzer check

Comparison now required

Blinking „o“

Child lock function in use

27

Page 43
Image 43
Thermador PRG30, PRG48, PRG36, PDR30, PDR36, PDR48 manual Gaggenau