Thermador PDR48, PRG48, PRG30, PRG36, PDR30, PDR36 manual Error, Cause, Corrective Action

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 47
Image 47
Manual background

B

Error

Cause

 

Corrective Action

 

 

 

 

F42

Lower motorized latch will not

1.

Check P24 connector on the Power Board.

 

lock.

2.

Ensure door latch switches are operating properly.

 

 

3.

Check that neither latch switch nor common wires are pinched to

 

Defective or jammed lower

 

the appliance chassis.

 

oven door or latch switches.

4.

Check P10 connector and check if latch motor wire is pinched to

 

 

 

the appliance chassis.

 

Defective latch motor or its

5.

If F42 persists, replace Power Board.

 

wiring.

 

 

 

 

 

 

F43

Upper (or single) oven

1.

Check P4 connector on the Power Board.

 

motorized latch will not unlock.

2.

Ensure door latch switches are operating properly.

 

 

3.

Check that neither latch switch nor common wires are pinched to

 

Defective or jammed upper

 

the appliance chassis.

 

oven door or latch switches.

4.

Check P10 connector and check if latch motor wire is pinched to

 

 

 

the appliance chassis.

 

Defective latch motor or its

5.

If F43 persists, replace Power Board.

 

wiring.

 

 

 

 

 

 