Thermador PRG48, PRG30, PRG36, PDR30, PDR36, PDR48 manual Thermador, Error Codes

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 36
Image 36
Manual background

Thermador®

Thermador ESC30 and GSC30 30 inch range error codes

Error Codes

Causes

Example

Corrective Action

F6

Missing APPLIANCE

If 60 cycles is missing for one

Cancel key will reset

 

CHASSIS line cycle

minute

 

 

detector

 

 

F7

Function key stuck or

Stuck key

Must power down to clear this error. If key

shorted

remains stuck, replace clock assy.

 

 

 

 

 

 

F8

Analog/Digital supervisory

Will cancel cook mode

Reset with cancel key, if persists, replace clock

assy.

 

 

 

 

 

 

 

F9

Door latch supervisory

Will cancel clean mode

Check door latch if latch is OK, replace clock.

 

 

 

 

Note 1

Oven sensors should measure 1050

 

ohms at 75 degrees F. if the sensor

 

measures correctly (within 10%),

 

check each leg of the sensor to

 

ground and to each phase of the

 

electrical supply. If all checks OK,

 

check the contacts inside the molex

 

plug. If the spring contacts are bent

 

or crushed, the sensor will create

 

intermittent errors.

20