Thermador PDR36, PRG48, PRG30, PRG36, PDR30 Error, Cause, Corrective Action, F125, F126, F127, F141

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 52
Image 52
F125

B

Error

Cause

 

Corrective Action

 

 

 

 

F125

[Upper Cancel] or [Cancel] for

1.

Check all connections between keyboard (J1) and Display

 

single oven key circuit problem.

 

Board (P5).

 

Bad connection or bad Display or

2.

If OK, replace keyboard or Display Board or both.

 

 

 

 

keyboard.

 

 

F126

[Lower Cancel] key circuit

1.

Check all connections between keyboard (J1) and Display

 

problem.

 

Board (P5).

 

Bad connection or bad Display or

2.

If OK, replace keyboard or Display Board or both.

 

 

 

 

keyboard.

 

 

F127

[Cancel] key redundant return

1.

Check all connections between keyboard (J1) and Display

 

problem.

 

Board (P5).

 

Bad connection or bad Display or

2.

If OK, replace keyboard or Display Board or both.

 

 

 

 

keyboard.

 

 

F141

Slave micro not functioning.

1.

Check power and Display Board connectors P1B and associated

 

Bad connection or bad Display or

 

wiring.

 

2.

If OK, replace Power Board.

 

keyboard.

3.

If fault persists, replace Display Board.

 

 

 

 

36

Page 52
Image 52
Thermador PDR36, PRG48, PRG30, PRG36, PDR30, PDR48 manual Error, Cause, Corrective Action, F125, F126, F127, F141