B
WFR 2460 Washer Fault Codes
The last 8 fault codes are stored & displayed!
T1: Error (error displays).
The programme can be ended with the “Start / Pause” button. The errors can be selected with the “Menu” button. Only the errors of the last 8 wash programmes are stored and displayed.
Sequence:
Time/Operation |
| Display |
|
|
|
| Note |
| ||
HINTS: # of errors |
|
|
|
|
|
| The error frequency is | |||
| >>MENU T1: ERRORS |
|
| |||||||
reads “0” for faults |
|
|
| displayed on the lower line | ||||||
which didn’t occur. |
| 7- Er : 12 |
|
|
| and the error number on the | ||||
Look at # of errors, |
|
|
|
|
|
| right. |
| ||
|
|
|
|
|
|
| ||||
not error #, to see if |
|
|
|
|
|
| Hint: Scroll thru all errors to | |||
faults occurred. |
| Number of errors | Error # |
| ||||||
|
|
|
|
|
|
|
| check if any occurred. | ||
|
|
|
|
|
|
| ||||
Display | Error |
| Possible Cause |
|
| Remedial action | ||||
Er: 01 | Door open |
| Door switch not actuated |
| Close door, check lock | |||||
Er: 02 | Door lock cannot be |
|
|
|
|
|
|
| ||
| released |
|
|
|
|
|
|
|
| |
Er: 03 | Door lock cannot be |
|
|
|
|
|
|
| ||
| locked |
|
|
|
|
|
|
|
| |
Er: 04 | Door actuation | Triac defective / relay |
|
| Replace controller | |||||
| defective |
| stuck |
|
|
|
|
|
| |
Er: 05 | NTC interruption | Cable break / NTC |
|
| Rectify cable short – | |||||
|
|
|
| damaged |
|
|
|
|
| circuit / replace NTC |
Er: 06 | NTC | Cable |
| Rectify cable short- | ||||||
|
|
|
| damaged |
|
|
|
|
| circuit / replace NTC |
Er: 07 | Unexpected heating | Temperature increase |
|
| Start T/P 18 heater test | |||||
|
|
|
| without actuation of |
|
| programme | |||
|
|
|
| heater |
|
|
|
|
|
|
Er: 08 | Heating time exceeded | After 105 min. | Start T/P18 heater test |
|
|
| programme |
Er: 09 | Uncontrolled motor | Motor triac defective | Start T/P4 motor test |
| acceleration |
| programme. |
Er: 10 | Motor does not rotate | No / incorrect tacho- | Start T/P4 motor test |
|
| generator signal | programme. |
Er: 11 | Reversing relay test |
| Start T/P4 motor test |
| not passed |
| programme. |
Er: 12 | Flow rate sensor | Sensor / line | Check line |
| detects low water level |
| Replace sensor |
Er: 13 | Water inlet time | Water inlet / sensor | Start T/P11 sensor |
| exceeded |
| test programme |
Er: 14 | Water inlet time | W controller after 6 | Start T/P9 controller |
| exceeded | min. | test programme |
Er: 15 | Pumping time | 0 level not reached | Check pump circuit |
| exceeded | within 6 min. |
|
Er: 16 | Safety level reached |
| Start T/P8 and 9 level |
|
|
| test programme |
Er: 17 | Pressure sensor |
| Check line |
|
|
| Replace sensor |
Er: 18 | Calibration of pressure |
| Start T/P8 level test |
| sensor not possible |
| programme |
Er: 19 | Aqua stop fault | Aqua stop actuated | Eliminate leaks |
Er: 20 | Turbidity sensor | Calibration not | Start T/P10 sensor |
|
| possible | test programme |
Er: 21 | Update |
|
|
Er: 22 | Spin cycle terminated | After 15 | Start T/P4 motor test |
|
| attempts | programme |
Er: 23 | Foam detected | Via analogue sensor | Consult customer |
|
|
| about dosing |
42