Fault

B

WTMC Service Tips - - Test program (4B): Fault Codes

WTMC Dryer Test Program Fault Codes

Fault

 

 

 

 

Code

Fault

Solution

Notes

Effect

E:23

Model variant doesn’t

Replace faulty control module.

 

Dryer stops &

 

match table

 

 

can’t be

 

 

 

 

restarted.

E:24

Software version

Replace faulty control module.

 

Dryer stops &

 

doesn’t match table

 

 

can’t be

 

 

 

 

restarted.

E:25

Damaged data table

Replace faulty control module.

 

Dryer stops &

 

 

 

 

can’t be

 

 

 

 

restarted.

E:26

Control error

Replace faulty control module.

 

Dryer stops &

 

 

 

 

can’t be

 

 

 

 

restarted.

NOTE: Fault displayed alternates with # of times fault occurred every two (2) seconds. If there’s no faults, displays will be blank.

E:xx = fault code from E11 – E39 (e.g. E:11)

C:xx = # of occurrences (e.g. C:01)

NOTE: When test program is initially entered, last fault code will show. Display will be cleared once any test is started.