WFK 2401 Washer Fault Codes

Fault

Faults

 

Possible Causes/Notes

Corrective Actions

Code

 

 

 

 

09

NTC failed

NTC open circuited.

Disconnect NTC and measure resistance at terminals (~5.4 – 6.5 kΩ @

 

 

NOTE: Fault code occurs during test program.

20°C (68°F)). Replace NTC if faulty.

 

 

 

10

NTC failed

NTC shorted

Disconnect NTC and measure resistance at terminals (~5.4 – 6.5 kΩ @

 

 

NOTE: Fault code occurs during test program.

20°C (68°F)). Replace NTC if faulty.

 

 

 

12

Drum motor

Reversing relays have failed.

Check voltage at motor connectors when motor is energized. If voltage

 

reversing

 

 

doesn’t reverse, replace faulty control module.

 

relays failed

NOTE: Fault code occurs during test program.

 

 

 

 

 

 

NOTES:

While running water inlet valves, pressure switch, heater & drain pump test, display shows fault codes 01 since water doesn’t totally fill & 02 since water isn’t heated. This is normal.