Thermador PRG30, PRG48, PRG36, PDR30, PDR36, PDR48 manual Service Tips – Fault Codes

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 13
Image 13
Service Tips – Fault Codes (1)

B

Service Tips – Fault Codes (1)

DISHWASHER TEST PROGRAM ERROR CODES (on 2&3-digit digital displays):

00

0- No faults

 

1- Aqua Sensor (Sensotronic) fault

 

 

2- Heating system fault (heater, Hi-Limit, flow switch, NTC, control heater relay)

000

4- Water filling fault

 

TIP: Fault codes add up for multiple faults

 

8- NTC (temperature sensor) fault

 

(e.g. heating + water filling fault = 2 + 4 = 6

 

16- Water switch fault

 

 

 

 

 

 

 

 

 

DISHWASHER TEST PROGRAM ERROR CODES (on 2&3-digit digital displays):

00

F-

Water filling fault (underfill, overfill or water in the base)

2H-

Last wash cycle too long (> 99 minutes). Can be cold inlet water or heating

 

system fault (heater, Hi-Limit, flow switch, NTC, control module heater relay).

000

F-

Delay Start feature (not a fault code)

 

 

 

 

 

HINT: Apexx heater runs during steps 05 - 08.

Press “-“ button to skip to test 05 to measure heater amp draw.

DISHWASHER TEST PROGRAM ERROR CODES (on lower line of full text Apexx SH 99 displays):

S3 - No faults

A – Aqua Sensor (red) fault B – Aqua Sensor (green) fault

E – Water switch fault (no pulses detected) F – Water filling fault

G – Water switch fault (won’t stop running)

H – Heating system fault (heater, Hi-Limit, flow switch, NTC, control module heater relay)

K- NTC fault (short-circuited or open-circuited)

Xx – Test program step count (testing done when = 00) TIP: Top line shows wash cycle & bottom line shows fault code.

S- - 3- - - - - - - - - - - - - - - - - Start

 

 

 

 

- - - - - - - - - - - - - -In Cycle 0

 

S3

 

 

 

 

STEP

 

S3

00

 

 

 

 

 

 

 

 

 

 

S3

00

 

 

 

 

 

 

HINT: Dishwasher test program heat water to 150°F, so test programs will generally run > 20 minutes for incoming water temperatures ~ 120°F

HINT: Open door to select test program for fully-integrated models, then close door to run program.

NOTE: Flow through heaters heat water ~ 2°F/minute.

Page 13
Image 13
Thermador PRG30, PRG48, PRG36, PDR30, PDR36, PDR48 manual Service Tips – Fault Codes