CT and CMT Ovens with Dreefs Control Error Codes…continued

Error Codes

Causes

Example

Corrective Action

E8

Control bd

Remains in display oven

Replace control bd

 

 

unusable

 

E9

Latch

Latch motor may run but

Replace latch in affected oven.

switches do not cycle

 

 

 

 

 

 

 

E10

Control bd

Checksum error

Replace dreefs bd.

 

 

 

 

E11

Latch problem

Will not clean

Replace latch in affected oven.

 

 

 

 

E12

Latch problem

Will not clean

Replace latch in affected oven.

 

 

 

 

E13

Latch problem

Latch does not run

Check for voltage to latch motor.

 

 

 

 

E14

Latch problem

Loose latch switch

Check latch for proper operation.

 

 

 

 

E15

Control bd.

Remains in display oven

Replace dreefs bd.

unusable

 

 

 

 

 

 

 

Note 1 Oven sensors should measure 1050 ohms at 75 degrees F. If the sensor measures correctly (within 10%), check each leg of the sensor to ground and to each of the electrical supply. If all checks OK, check the contacts inside the molex plug.

If the spring contacts are bent or crushed, the sensor will create intermittent demos.