Thermador PDR30, PRG48 Thermador, Corrective Action, Water valve, relay board, should be none

Models: PDR48 PDR36 PDR30 PRG36 PRG30 PRG48

1 67
Download 67 pages 43.12 Kb
Page 39
Image 39
Water valve, relay board

Thermador®

Error codes for Gaggenau Steam Oven model ED-220/221…continued

Error Code Cause

Example

Corrective Action

F72

F73

F74

Base pan sensor

Defective electronics

Replace relay board

Main water valve not

Check incoming water

Water valve, relay board

closing properly

pressure (must be

 

 

minimum 16 PSI) check

 

Pressure switch stays

power to valve pressure

Indicates pressure in system when there

switch stuck closed or

closed

should be none.

main valve stuck open.

 

 

 

 

 

Note 1

 

Note 2

The food probe in this oven is a PTC 1000 sensor. It is not

 

unpluggable and is tested the same as in Note 1

Note 3

The oven has a very comprehensive diagnostic program.

 

Instruction are located in the Gaggenau 2000 Service Manual.

Note 4

The program is kept in the display head on this oven. If the

 

display is replaced, the parameters must be programmed into the

 

new board. Specific instruction are listed in the Gaggenau 2000

 

Service Manual

23

Page 39
Image 39
Thermador PDR30, PRG48 Thermador, Corrective Action, Water valve, relay board, Indicates pressure in system when there