Blade Changes
Always disconnect power to the machine when changing blades. Failure to do this may result in serious personal injury.
All saw blades are dan- gerous and may cause personalinjury.Toreduce the risk of being injured, wear leather gloves when handling saw blades.
To replace the blade:
1.DISCONNECT BANDSAW FROM POWER!
2.Release the tension lever.
3.Remove the table insert and the table pin. Adjust the upper and lower guide blocks away from the blade.
4.Open the upper and lower wheel covers and slide the blade off both wheels.
5.Rotate the blade 90˚ and slide it through the slot in the table.
6.Slide the blade through the table slot, ensur- ing that the teeth are pointing down toward the table. If the teeth will not point downward in any orientation, the blade is
7.Slip the blade through the guides, and mount it over the upper and lower wheels.
8.Apply tension.
G0621 Wood/Metal Bandsaw
9.Turn the tension knob until proper blade ten- sion has been reached according to the blade thickness scale shown in Figure 39.
Tension Scale