Control Panel

A

B

C

D

E

F

G

H

I

M

K

J

L

Figure 23. G0664 control panel.

A.Power Indicator Light: Indicates the main power to the machine is turned ON.

B.Cutting Fluid Switch (): Turns the cut- ting fluid pump to Manual/OFF/Auto.

C.Vise Open Button (): Hydraulically opens the vise approximately 38" to release workpieces between cuts.

D.Raise Bow Button (): Hydraulically raises the saw blade. Will continue raising the blade until the upper limit switch is reached or the button is released.

E.Saw Motor Start Button (HI6GI ): Turns the saw motor ON/OFF.

F.Standby Button (11> ): Powers control panel and readies all functions for use. Must be pressed after safety stop button is reset.

G.Vise Close Button (): Hydraulically closes the vise approximately 38". Must be activated before saw motor will turn ON.

H.Lower Bow Button (): Hydraulically lowers the saw blade at the rate determined by the downfeed knob (L).

I.Blade Speed Switch (ADL D;; =><= ): Controls the speed of the blade (LOW/OFF/HIGH).

J.Laser Light ON/OFF Switch ( ): Turns the laser alignment function ON/OFF.

K.Safety STOP Button ( HIDE ): When pressed, turns OFF saw motor, hydraulic motor, and cutting fluid motor. DOES NOT CUT POWER TO MACHINE! To reset, turn the button clockwise until it pops back out.

L. Blade Downfeed Knob (

&

%

.

 

): Controls

 

'

 

 

-

 

 

(

 

 

,

 

 

)

* +

 

 

the rate at which the blade feeds into the workpiece.

M.ON/OFF Switch: Turns machine ON/OFF.