SECTION 3: CIRCUIT REQUIREMENTS

110V Operation

If the machine is not wired correctly a fire could result. Make sure your wiring, recep- tacle, plug, and circuit breaker can handle the current draw of the machine. If you are not sure that your electrical circuit can han- dle the current draw, get a qualified electri- cian to test your electrical system and do any required upgrades. Do not attempt to modify an existing circuit by only replacing the circuit breaker with one rated for a high- er amperage draw than the wiring, recepta- cle, and plug are rated for.

The Models SM, Z & ZF motors are prewired to operate at 110V. See Figure 5 for a typical 110V plug and outlet.

Models SM & Z:

Under normal 110V use, the Models SM & Z motors draw approximately 16 amps. Use a 20 amp circuit breaker or a 20 amp slow-blow fuse.

Model ZF:

Under normal 110V use, the Model ZF motor draws approximately 17 amps. Use a 20 amp cir- cuit breaker or a 20 amp slow-blow fuse.

Figure 5. Typical 110V 3-prong plug and outlet.

The circuit you use should be dedicated, (i.e., the machine should provide the only draw from that circuit). If frequent circuit failures occur when using this machine, contact our Service Department or your local electrical contractor.

G1022 Series Table Saws

-9-