Hampton Direct H25-NG1, H25-LP1 Note The pipe seam should be facing down, Note If installing ter

Models: H25-LP1 Propane H25-NG1, H25-LP1

1 48
Download 48 pages 23.62 Kb
Page 20
Image 20
Note: The pipe seam should be facing down.

INSTALLATION

3)Attach the 4" dia. fl ex liner to the vent ter- minal ensuring that the fl ex overlaps the collar of the vent terminal by a minimum of 1-3/8"(35mm). Use Mill-Pac to seal and secure with 3 of the #8 x 1/2" screws (stainless steel).

4)Attach the adjustable pipe section to the vent terminal using Mill-Pac and/or high temperature silicone and attach with 3 of the #8 x 1/2" screws (stainless steel).

NOTE: For best results and optimum per- formance with each approved vent- ingsystem,itishighlyrecommended toapply“Mill-Pac”sealant(supplied) to every inner pipe connection. Fail- ure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional.

Note: The pipe seam should be facing down.

Note: To make the installation more aes- thetically pleasing, we recommend framing out a square that the cap can be mounted on.

Note: If installing ter-

mination on a siding covered

wall, a vinyl sid- ing standoff or furring strips must be used to ensure that the termination is not recessed into the

siding. For vinyl siding standoff installation refer to the Dura-Vent Termination instructions.

5)Slide the partially connected pipe and vent terminal assembly through the wall thimbles (from the exterior into the interior) and secure the cap to the exterior wall with 4 of the supplied screws (#8 x 1-1/2" drill point, stainless steel). Note: pilot holes will need to be drilled through the wall thimble on all 4 corners.

Note: The four screws provided for the vent cap should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

6)A bead of non-hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff.

7)Stretch the 4" dia. fl ex liner out fully and get a trial fi t of the liner onto the 4" dia. starter collar.

8)Cut the 4" dia. fl ex liner to the desired size.

Hint: leave an extra 12" to 16" of length, this will make the fi nal assembly easier to work with.

9)Secure the 4" dia. fl ex liner to the 4" adapter with Mill-Pac and 3 of the #8 x 1/2" screws (stainless steel).

10)Slide the decorative Thimble Cover over the pipe sections and secure with 4 screws (#8 x 1-1/2" drill point, black) to the wall.

11)Slide the 90o elbow (crimp end up), the 45o elbow and the 4 ft. pipe section (crimp end up) over the 4" dia. fl ex liner.

12)Install the spring spacers onto the pipe sec- tions.

13)Secure the 4" dia. fl ex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel).

14)Attach the 45o elbow onto the starter collar by sealingwithMill-Pacand/or hightemperature silicone and securing with 3 of the #8 x 1/2" (black) screws.

15)Attach the pipe section to the 45o elbow by sealingwithMill-Pacand/or hightemperature silicone and securing with 3 of the #8 x 1/2" screws (black). Pipe seams should be facing the wall.

16)Attach the 90oelbow onto the pipe section by sealingwithMill-Pacand/or hightemperature silicone and securing with 3 of the #8 x 1/2" screws (black).

17)Slide the adjustable pipe section onto the 90o elbow. Slide the trim collar over the adjust- able pipe sections to cover the joint of the telescopic section.) The fl ex may have to be compressed back in order for the adjustable pipe to properly mate to the elbow. Seal with Mill-Pacand/orhightemperaturesiliconeand secure with 3 of the #8 x 1/2" screws (black). Pipe seams facing down.

18)Install the trim collar over the starter collar and secure with a #8 x 1/2" screw (black).

If the pipe needs to be touched up, use only Stove Brite High Temperature Metallic Black Stove Paint.

20

Hampton® H25-1 Direct Vent Freestanding Gas Stove

Page 20
Image 20
Hampton Direct H25-NG1, H25-LP1, H25-LP1 Propane Note The pipe seam should be facing down, Note If installing ter