Hampton Direct H25-NG1, H25-LP1, H25-LP1 Propane installation manual H1 H

Models: H25-LP1 Propane H25-NG1, H25-LP1

1 48
Download 48 pages 23.62 Kb
Page 16
Image 16
H1

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

With these options, maxi-

 

 

 

 

mum total pipe length is 30

A)

2'

Min.

4' Max.

 

 

 

 

feet with minimum of 6 feet

B)

3'

Min.

5' Max.

total vertical and maximum

C)

4'

Min.

6' Max.

8 feet total horizontal.

D)

5'

Min.

7' Max.

Please note minimum 1

E)

6'

Min.

8' Max.

foot between 90o elbows

 

 

 

 

is required.

Lengths do not include elbow indicated

H1

 

Vent restrictor position A (fully open), refer to the

 

"Vent Restrictor Position" section.

 

 

 

V

H

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H

V

H + H1 With these options, max.

A)1' Max. 1' Min. 3' Max. total pipe length is 30 feet with min. of 8 feet total

B)2' Max. 2' Min. 5' Max. vertical and max. 8 feet

C)3' Max. 4' Min. 6' Max. total horizontal.

D)4' Max. 6' Min. 7' Max. Please note min. 1 foot

E)5' Max. 8' Min. 8' Max. between 90o elbows is required.

Lengths do not include elbow indicated

Vent restrictor position A (fully open), refer to the "Vent

Restrictor Position" section.

H1

H

V

16

Hampton® H25-1 Direct Vent Freestanding Gas Stove