62 code identifier for Code 39
9999 code length that must match for Code 39, 9999 = all lengths
41start character match for Code 39, 41h = “A” FF termination string for first code
6A code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all lengths
42start character match for Code 128, 42h = “B”
FFtermination string for second code
69 code identifier for Code 93
9999 code length that must match for Code 93, 9999 = all lengths 43 start character match for Code 93, 43h = “C”
FF termination string for third code
To program the previous example using specific lengths, you would have to count any programmed prefixes, suffixes, or formatted characters as part of the length. If you use the example on page
SEQBLK62001241FF6A001342FF69001243FF
The breakdown of the command line is shown below:
SEQBLK | sequence editor start command |
62 | code identifier for Code 39 |
0012 | A - Code 39 sample length (11) plus CR suffix (1) = 12 |
41 | start character match for Code 39, 41h = “A” |
FFtermination string for first code
6A code identifier for Code 128
0013 B - Code 128 sample length (12) plus CR suffix (1) = 13
42start character match for Code 128, 42h = “B”
FF termination string for second code
69 | code identifier for Code 93 |
0012 | C - Code 93 sample length (11) plus CR suffix (1) = 12 |
43 | start character match for Code 93, 43h = “C” |
FF | termination string for third code |
IMAGETEAM™ 2020/5620 System Manual | 3 - 11 |