Programming the Scanner

Condensed Data Editor

Data Replacer Settings

PROGRAM

 

 

 

 

 

 

 

END(Exit)

 

 

 

 

 

 

 

 

 

Family Code Selection

 

 

Parameter Selection

 

 

Option Code

 

2nd Option Code

Replacer Control

 

 

Disable

 

 

FIN

 

 

 

 

 

Select one bar code symbology

 

 

(2 digits)

 

automatic termination

 

 

 

Select all bar code symbologies

 

00

 

automatic termination

 

 

 

 

 

 

 

 

 

1st Replacement

 

 

Disable

 

 

FIN

 

 

 

 

 

Enable

 

 

(2-digit decimal

 

[ 00-7F ]

 

 

 

 

 

 

value)

 

 

 

 

 

2-digits identified position; 1 replacement character

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2nd Replacement

 

 

Disable

 

 

FIN

 

 

 

 

 

Enable

 

 

(2-digit decimal

 

[ 00-7F ]

 

 

 

 

 

 

value)

 

 

 

 

 

2-digits identified position; 1 replacement character

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3rd Replacement

 

 

Disable

 

 

FIN

 

 

 

 

 

Enable

 

 

(2-digit decimal

 

[ 00-7F ]

 

 

 

 

 

 

value)

 

 

 

 

 

2-digits identified position; 1 replacement character

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FACTORY DEFAULT

The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for replacer control, and provides Multiple Position Replacement in the identified position.

All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position. While the Data Replacer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID, or Record Suffix.

Please refer to page 3-37 for information about the “Bar Code Selection” and “Position Calculation” of Data Replacer. To determine the hex value for the “Character,” refer to the HEX/ASCII Table listed on page A-6.

Refer to page 3-12 for 2-digit symbology option code.

3-35

Page 49
Image 49
Hand Held Products 3220, 3060 Data Replacer Settings, Replacer Control, 1st Replacement, 3rd Replacement, 2nd Replacement