Programming the Scanner

Program & End

Scan

PROGRAM

Scanner enters programming mode,

and inhibits all non-programming functions.

Scan

END

Scanner exits programming mode, and stores all

parameters in Flash Memory ASIC or non-volatile memory,

then issues the completion beep (3 short beeps).

System List & Master Default

Scan “SYSLIST

Scanner lists the product information and

revision number to host via selected host interface, then issues the completion beep (3 short beeps).

Scan “M_DEFAULT

Scanner returns all programmable

parameters to factory preset configurations,

then issues the completion beep (3 short beeps).

Please note that the scanner will take 3-4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the “END.” Please do not turn off the power before the completion beep. It may destroy all configured parameters.