Programming the Scanner

Serial Interface Control

Baud Rate & Data Frame Setting

PROGRAM

 

 

 

 

 

END(Exit)

 

 

 

 

 

 

 

 

Family Code Selection

 

 

Parameter Selection

 

Option Code

Handshaking Protocol

 

None (free running mode)

 

 

 

 

0

 

 

RTS/CTS (hardware handshaking)

 

 

1

 

 

ACK/NAK (software handshaking)

 

 

2

 

 

Xon/Xoff (software handshaking)

 

 

3

 

 

 

 

 

 

 

 

 

Baud Rate (BPS)

 

38.4K BPS

 

2400 BPS

 

0

 

4

 

 

19.2K BPS

 

1200 BPS

 

1

 

5

 

 

9600 BPS

 

600 BPS

 

2

 

6

 

 

4800 BPS

 

300 BPS

 

3

 

7

Data Frame

 

8, None, 1

 

7, Space, 1

 

0

 

8

 

 

8, Odd, 1

 

7, Mark, 1

 

1

 

9

 

 

8, Even, 1

 

7, None, 2

 

2

 

A

 

 

8, Space, 1

 

7, Odd, 2

 

3

 

B

 

 

8, Mark, 1

 

7, Even, 2

 

4

 

C

 

 

8, None, 2

 

7, Space, 2

 

5

 

D

 

 

7, Odd, 1

 

7, Mark, 2

 

6

 

E

 

 

7, Even, 1

 

 

 

7

 

 

Time Out Control

 

None

 

1 second

 

0

 

3

 

 

200 mseconds

 

2 seconds

 

1

 

4

 

 

500 mseconds

 

5 seconds

 

2

 

5

 

 

 

 

User defined value (seconds)

 

 

 

6, (2 digits)

FACTORY DEFAULT

When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication.

When the ACK/NAK Software Handshaking option is selected, the scanner waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, the scanner will re-send the data until receiving ACK.

The Time Out Control is a pre-defined delay time for the scanner to wait for handshaking, acknowledgment, or non-acknowledgment from the host computer.

3-25

Page 39
Image 39
Hand Held Products 3060, 3220, 3080 Baud Rate & Data Frame Setting, Time Out Control, Handshaking Protocol, Baud Rate BPS