Programming the Scanner

Serial Interface Control

Record Suffix, Handshaking & Time Out Setting

PROGRAM

 

 

 

 

END(Exit)

 

 

 

 

 

 

Family Code Selection

 

 

Parameter Selection

 

Option Code

STX/ETX Control

 

 

Disable STX/ETX transmission

 

0

 

 

 

Enable STX/ETX transmission

 

1

 

 

 

 

 

 

 

 

 

STX/ETX are two characters used to indicate the starting and ending of the total

 

 

 

 

 

data frame transmitted via serial interface.

 

 

 

 

 

 

 

 

Record Suffix

 

 

None

 

0

 

 

 

CR (0DH)

 

1

 

 

 

LF (0AH)

 

2

 

 

 

CRLF (0D0AH)

 

3

 

 

 

TAB (09H)

 

4

 

 

 

SPACE (20H)

 

5

 

 

 

EOT (04H)

 

6

 

 

 

User defined character (1 character)

 

7, (00-7F)

Preamble

 

 

None

 

FIN

 

 

 

1-15 characters

 

[00-7F],[FIN]

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

Postamble

 

 

None

 

FIN

 

 

 

1-15 characters

 

[00-7F],[FIN]

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

FACTORY DEFAULT

 

 

 

 

 

The record suffix and postamble differ in that the record suffix is always last and follows a postamble.

Serial Interface Message String :

STX

Preamble

Data Length

Prefix Symbol ID

Scanned Data

Suffix Symbol ID

Postamble

ETX

Record Suffix

1 character

1-15 characters

2-3 digits

1 or 2 characters

variable length

1 or 2 characters

1-15 characters

1 character

1 character

3-24

Page 38
Image 38
Hand Held Products 3080, 3060 Serial Interface Control, Record Suffix, Handshaking & Time Out Setting, STX/ETX Control