Programming the Scanner

Condensed Data Editor

Data Verifier Settings

PROGRAM

 

 

 

 

 

 

 

 

END(Exit)

 

 

 

 

 

 

 

 

 

 

Family Code Selection

 

 

Parameter Selection

 

 

Option Code

 

 

2nd Option Code

Verifier Control

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Select one bar code symbology

 

 

(2 digits)

 

 

automatic termination

 

 

 

Select all bar code symbologies

 

00

 

 

automatic termination

 

 

 

 

 

 

 

 

 

 

Identified Data Length

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Enable

 

 

(2-digit decimal

 

 

 

 

 

 

 

 

 

value)

 

 

 

 

 

 

Determine the identified data length for verification.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st Identified Character

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Enable

 

 

(2-digit HEX

 

 

[00-7F]

 

 

 

 

 

 

value)

 

 

 

 

 

 

2-digits checking position; 1 identified character

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2nd Identified Character

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Enable

 

 

(2-digit HEX

 

 

[00-7F]

 

 

 

 

 

 

value)

 

 

 

 

 

 

2-digits checking position; 1 identified character

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3rd Identified Character

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Enable

 

 

(2-digit HEX

 

 

[00-7F]

 

 

 

 

 

 

value)

 

 

 

 

 

 

2-digits checking position; 1 identified character

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter.

All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the scanner will not transmit the data to the host computers, but will instead issue 3 long beeps for verification error and skip the scanned data.

The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID, or Record Suffix. Please refer to page 3-37 for information about the “Bar Code Selection” and “Position Calculation” of Data Verifier.

To determine the hex value for the “Character,” refer to the HEX/ASCII Table on page A-6. Refer to page 3-12 for 2-digit symbology option code.