Hearth and Home Technologies CNXT4236IH Vent Diagrams, Top Vent Horizontal Termination, One Elbow

Models: CNXT4236ILH CNXT4236IH CNXT4842IH CNXT4842ILT CNXT4236ILT CNXT4842IT CNXT4236IT CNXT4842ILH

1 80
Download 80 pages 27 Kb
Page 23
Image 23

E. Vent Diagrams

To replace the first starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows.

General Rules:

SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally.

SUBTRACT 1-1/2 ft. from the total H measurement for each 45° elbow installed horizontally.

A maximum of three 90° elbows (or six 45° elbows) may be used in any vent configuration. Some elbows may be installed horizontally. See Figure 7.9.

Elbows may be placed back to back anywhere in the system as long as the first 90° elbow is a starter elbow except as shown in Figure 7.4.

When penetrating a combustible wall, a wall shield firestop must be installed.

When penetrating a combustible ceiling, a ceiling firestop must be installed.

Horizontal runs of vent do not require vertical rise; horizontal runs may be level.

1. Top Vent - Horizontal Termination

One Elbow

V1

H1

V1 min.

V1 max.

H1 max.

ft

m

ft

m

ft

m

0

0.00

-

-

1.5

0.46

0.5

0.15

-

-

6

1.83

 

 

 

 

 

 

1

0.30

-

-

11

3.35

1.5

0.46

-

-

18

5.49

2

0.61

-

-

25

7.62

 

 

 

 

 

 

 

DVP

25

7.62

25

7.62

 

SLP

23

7.01

23

7.01

You may install a DVP elbow directly on top of the

CNXT4236 and on top of the CNXT4842.

Figure 7.3

Note: The CNXT series appliances can adapt to SLP series vent pipe when venting off the top of the appliance. You must use a DVP-SLP24 adapter which can only be attached to the appliance starting collar.

When looking at horizontal termination diagrams, the adapter is not counted as part of the minimum vertical (V1 min.) requirements.

Whether horizontal or vertical termination, the adapter is counted as part of the maximum vertical limitations.

All venting rules for the vent run must still be followed.

HORIZONTAL EXAMPLE

V1 = 1 ft.

H1 = 11 ft. max.

DVP

V1 = 1 ft.

H1 = 11 ft.

max

DVP-SLP24

SLP

VERTICAL EXAMPLE

 

 

 

 

DVP-SLP24

12 ft (3.66 m) min.

12 ft (3.66 m) min.

Adapter

60 ft (18.29 m) max.

60 ft (18.29 m) max.

 

DVP

SLP

Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08

23

Page 23
Image 23
Hearth and Home Technologies CNXT4236IH, CNXT4842ILT, CNXT4842IH Vent Diagrams, Top Vent Horizontal Termination, One Elbow