E. Disassemble Vent Sections |
| • Use a | ||||||
• Rotate either section (see Figure 10.11) so the seams |
| system on the ceiling and drill a small hole through the | ||||||
| ceiling and roof at this point. Locate the hole and mark | |||||||
on both pipe sections are aligned as shown in Figure |
| |||||||
| the outline of the cathedral ceiling support box on the | |||||||
10.12. |
| |||||||
| outside roof. | |||||||
• Pull carefully to separate the pieces of pipe. |
| |||||||
| • Remove shingles or other roof covering as necessary | |||||||
|
| |||||||
|
| to cut the rectangular hole for the support box. Cut the | ||||||
|
| hole 1/8 in. (3 mm) larger than the support box outline. | ||||||
|
| • Lower the support box through the hole in the roof until | ||||||
|
| its bottom is at least 2 in. (51 mm) below the ceiling | ||||||
|
| (Figure 10.13). | ||||||
|
| • Level the support box both vertically and horizontally | ||||||
|
| and temporarily tack it in place through the inside walls | ||||||
|
| into the roof sheathing. | ||||||
|
| • Use tin snips to cut the support box from the top corners | ||||||
|
| down to the roof line and fold the resulting flaps to the | ||||||
|
| roof. See Figure 10.14. | ||||||
|
| • Nail the flaps to the roof AFTER running a bead of non | ||||||
|
| hardening sealant between the flaps and the roof. | ||||||
|
| WARNING! Risk of Fire! Clean out ALL materials from | ||||||
|
| inside the support box and complete the vertical vent run | ||||||
Figure 10.11 Rotate Seams for Disassembly |
| and termination. | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Level | |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| Cathedral ceiling | |
|
|
|
|
|
|
| support box | |
|
|
|
|
|
|
|
| 2 in. (51 mm) |
|
|
|
|
|
|
|
| minimum below |
|
|
|
|
|
|
|
| finished ceiling |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Cut hole 1/8 in. (3 mm) greater | ||
Figure 10.12 Align and Disassemble Vent Sections |
|
|
|
| ||||
|
|
|
|
| in size than pattern of support | |||
|
|
|
|
|
| |||
|
|
|
|
|
| box as it is projected onto | ||
|
|
|
|
|
| roofline. | ||
F. Install Decorative Ceiling Components |
|
|
|
|
|
|
|
|
(SLP only) |
| Figure 10.13 | ||||||
|
|
A decorative ceiling thimble can be installed on a flat ceil- |
|
ing through which the vent passes. The decorative ceiling |
|
thimble is used to cover the firestop, which is installed |
|
according to section 8.C. |
|
• Seal the gap between the vent pipe and firestop |
|
using high temperature silicone to prevent cold air |
|
infiltration. |
|
• Install the decorative ceiling thimble by sliding it up to |
|
the ceiling and attaching it using the provided screws. |
|
A decorative black cathedral ceiling support box can be |
|
used where vertical vent runs pass through a cathedral |
|
ceiling. |
|
Figure 10.14 |
|
Heatilator • Caliber CNXT Series • | 45 |