F. Horizontal Termination

F. Horizontal Termination

Type A - Up & Out Installation

90° ELBOW

CENTER LINE

TERMINATION CAP

PIPE LENGTH

WALL THIMBLE/

HEAT SHIELD

WALL THIMBLE COVER

PIPE LENGTH Type A - Up & Out Installation

Type B - Straight Out Installation

SNORKEL KIT

15-5/8 in. (397mm)

WALL THIMBLE COVER

21 in.

(533mm)

CENTER

LINE

PIPE LENGTH

WALL THIMBLE / HEAT SHIELD

WALL STRAP 14 in. (356mm) Wide

Type C - 45° Elbow in Corner Installation

 

Wall Thimble/Heat Shield

45° Elbow

3/8 in. (10mm)

 

 

Clearance from

 

stove corner to

 

combustible wall

 

(for valve access

 

on side).

3/8 in. (10mm) Clearance from stove corner to combustible wall.

Figure 5.3

Step 1.

Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is being planned. If this is the case, you may want to adjust the location of the appliance.

Type B - Straight Out Installation WARNING

Fire Hazard.

Exhaust Fume Risk.

Impaired Performance of Appliance.

Ensure vent components are locked together correctly.

Pipe may separate if not properly joined.

Step 2.

Direct vent pipe is designed with a locking connection. To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory. Wall thickness may vary. Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs.

Note: Female ends of direct vent pipe/elbows are designed to slide straight onto the male ends of adjacent pipes by orienting the pipe indentations so they match and slide into the entry slots on the male ends, see Figure 5.4. Push the pipe sections completely together, then twist-lock one section clockwise approximately one-quarter turn, until the two sections are fully locked. The female locking lugs may not be visible from the outside. They may be located by examining the inside of the female ends.

Female Locking Lugs

Type C - 45° Elbow in Corner InstallationMale Locking Lugs

Figure 5.4

Step 1. WARNING

Fire Risk. Explosion Risk. Combustion Fume Risk.

Use vent run supports per installation instructions. Connect vent sections per installation instructions.

Maintain all clearances to combustibles.

Do NOT allow vent to sag below connection point to appliance.

Maintain specified slope (if required).

Improper support may allow vent to sag or separate.

August 1, 2008