Figure 8.6 Place cover plate and gasket over top vent and attach with the eight screws removed in Figure 8.2.
Figure 8.7 Insert inner collar adapter to rear flue vent.
C. Damper Adjustment
Refer to vent graph on page 12. If your installation falls within the range of the gray shaded area of graph, it may be necessary to make an adjustment to the vertical damper to improve the flame appearance in your appliance.
1. Top Vent Installations
CLOSED
OPEN
Figure 8.9 Locate the damper adjustment on the intake plenum, accessing through the appliance front. Adjustor is centered at the top of the appliance.
1.Loosen screws using a Phillips head screwdriver.
2.Pivot the vertical damper adjustor in 1/4 in. (6mm) increments while observing the activity.
3.Turn clockwise to open the damper = less flame height and more blue in flame color.
4.Turn counterclockwise to close damper = increased flame height and more yellow in flame color.
5.Make adjustment until flame size and activity suit your personal preference and then retighten screws on the adjustment control.
2. Rear Vent Installations
Figure 8.8 Install vent pipe adapter with gasket or
Place an appropriate grille (without a hole) gently into the opening on top of appliance.
Figure 8.10 The rear vent damper is located in the back of the firebox (behind the rear brick panel on the Tiara
1.Remove front/glass/ logs and brick (if installed).
2.Loosen screws and slide up to suggested settings.
3.Tighten screws
4.Reinstall front/glass/logs and brick (if applicable).
NOTE: In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor.