M. Optional Blower
KIT CONTENTS: Blower; speed control; lock nut; control knob; ground clip; temperature sensor switch; wing nut; 2
TOOLS REQUIRED: Philips head screwdriver; 1/2 in. wrench.
The
The blower system operates on 120 VAC, 60 Hz power. This is available through a receptacle in the factory installed junction box on the underside of the appliance.
BLOWER
CONTROL
KNOB
GROUND |
| WING | |
TEMP. | NUT | ||
CLIP | |||
| SENSOR |
| |
CONTROL | SWITCH |
| |
NUT |
|
| |
SPEED |
|
| |
CONTROL |
|
|
Figure 8.26 Compare CONTENTS OF CARTON with the actual parts received. If any parts are missing or damaged, contact your dealer before starting installation. Do not install a damaged blower kit.
Figure 8.27 From the rear of the appliance, slide the blower into the blower housing with the magnetic strips down. The blower openings should be at the front.
Plug blower power cord into fan outlet on junction box.
Figure 8.28 Attach grounding clip supplied with the kit to the blower housing. Attach ground wire to grounding clip.
WING NUT
Figure 8.29 Slide temperature sensor switch/bracket assembly onto the
Disconnect the two wire ends connected together on the junction box. Connect female end to one side of temperature sensor switch.
Connect one end of the black wire provided with the kit to the remaining wire end on junction box.
Feed loose ends of the black and blue wires through the orange grommet in fan housing.
3
SCREWS
Figure 8.30 Remove valve access cover from back of appliance by removing the three screws indicated.
August 1, 2008 | Heat & Glo · Tiara I B & Tiara II B · | Page 35 |