A. | 6 |
Gas Information
Fuel Conversions | Tiara |
|
Before making gas connections ensure that the appliance being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth & Home Technologies specified and approved parts.
1. Converting to LP Gas
NOTE: Gas conversions should only be performed by a qualified service person, and/or where required by state and local codes, licensed installer/service technician. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.
KIT CONTENTS: Replacement orifice; replacement pilot injector; valve regulator; conversion label.
TOOLS REQUIRED: Power drill (a 90° handle is help- ful); #2 Phillips bit; 7/16” wrench,. slotted screwdriver or Torx TH20, 5/32 in. Allen wrench, 5/8 in. open end wrench,
Remove front (if installed), glass, and logs (if installed.)
Figure 6.2 Using the #2 Phillips screwdriver remove the two
(2)1/4" x 20 screws securing the burner as indicated. Lift burner out of firebox.
Tiara I-B Burner Removal:
Figure 6.1 Remove the optional brick set, if installed. Remove the two screws, one on each side of burner. Retain fasteners for reinstallation. Lift burner up and out of the firebox.
Figure 6.3 Remove the burner support by loosening the left screw on the pilot tower, and removing the three screws on the front side of the burner neck support.
Slide the burner neck support to the left.
Page 24 | Heat & Glo · Tiara I B & Tiara II B · | August 1, 2008 |