Heat & Glo LifeStyle 6000TRS-CD manual Step Finishing, When Servicing Controls. Wiring Er

Models: 6000TRS-CD

1 42
Download 42 pages 3.32 Kb
Page 32
Image 32
LABEL ALL WIRES PRIOR TO DISCONNECTION

!WARNING: DO NOT CONNECT 230 VAC TO THE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED.

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION

 

WHEN SERVICING CONTROLS. WIRING ER-

 

RORS CAN CAUSE IMPROPER AND DANGER-

 

OUS OPERATION. VERIFY PROPER OPERA-

 

TION AFTER SERVICING.

OPTIONAL WALL SWITCH

 

 

THERMOSTAT OR REMOTE

 

 

 

 

THERMOCOUPLE

 

 

TP/TH

 

OFF

TP

 

TH

 

 

 

ON

THERMOPILE

 

ON/OFF

REMOTE SWITCH

GAS VALVE

SWITCH

PIGTAIL

 

 

 

Figure 29. Standing Pilot Ignition Wiring Diagram

Step 9

Finishing

Only non-combustible materials may be used to cover the black fireplace front.

The following diagram shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 , 3 and 4 for other fireplace clearances.

45o

30.5

27.9

25.4

22.7

20.3

15.8

12.715.2

7.6 10.2

5

TOP FRONT EDGE

OF FIREPLACE

NOTE: ALL DIMENSIONS SHOWN

IN CENTIMETERS

32

Figure 30. Minimum Vertical and Maximum Horizontal Dimensions of Combustibles

above Fireplace

!WARNING: WHEN FINISHING THE FIREPLACE, NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET GRILLES IN ANY MANNER.

Page 32
Image 32
Heat & Glo LifeStyle 6000TRS-CD Step Finishing, When Servicing Controls. Wiring Er, Ous Operation. Verify Proper Opera