Heat & Glo LifeStyle 6000TRS-CD manual Step The Gas Supply Line

Models: 6000TRS-CD

1 42
Download 42 pages 3.32 Kb
Page 30
Image 30
Step 6

30

Step 6

The Gas

Supply Line

The gas line should be installed by a qualified service technician.

NOTE: Have the gas supply line installed by a qualified service technician in accordance with all building regulations.

NOTE: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air.

NOTE: Consult local building regulations to properly size the gas supply line leading to the (Rp 1/2”) hook-up at the unit.

This gas inlet connection is ISO 7-Rp 1/2 (BSP Rp 1/2).

To install the gas supply line:

When attaching the pipe, support the control so that the lines are not bent or torn.

After the gas line installation is complete, use a soap solution to carefully check all gas connec- tions for leaks.

!WARNING:

DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

At the gas line access hole, use insulation to repack the space around the gas pipe.

Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.

GAS ACCESS

Figure 28

Page 30
Image 30