Troubleshooting Guide

 

 

 

Troubleshooting Guide

 

 

 

 

 

Error

Title

Cause of error

Check point & Normal condition

 

code

 

 

 

 

 

 

 

 

 

 

 

 

• Open / Short

Normal resistor : 10K/ at 25°C(77°F) (Unplugged)

 

44

Outdoor air sensor

• Soldered poorly

 

Normal voltage : 2.5Vdc / at 25°C(77°F) (plugged)

 

 

 

• Internal circuit error

 

 

 

 

 

 

 

 

 

 

 

 

• Open / Short

Normal resistor : 5K/ at 25°C(77°F) (Unplugged)

 

45

Condensor pipe sensor

• Soldered poorly

 

Normal voltage : 2.5Vdc / at 25°C(77°F) (plugged)

 

 

 

• Internal circuit error

 

 

 

 

 

 

 

 

 

 

 

 

• Open / Short

Normal resistor : 200K/ at 25°C(77°F) (Unplugged)

 

47

D-Pipe sensor

• Soldered poorly

 

Normal voltage : 4.5Vdc / at 25°C(77°F) (plugged)

 

 

 

• Internal circuit error

 

 

 

 

 

 

 

 

 

 

Check the resistance

Check Point

1.Estimate the resistance of each sensor.(Unplugged)

2.Estimate the voltage of each sensor.(Plugged)

3.If the resistance is 0V or 5Vdc, then sensor is abnormal

Service Manual 65

Page 65
Image 65
Heat Controller DMH18DB-1 Service Manual, Troubleshooting Guide, Title, Cause of error, Check point & Normal condition