Model OFE/OFG/OEA/OGA-341, 342

2-15. GAS CONTROL VALVE

REPLACEMENT (Continued)

5.Using a pipe wrench, loosen the outlet fitting to the burner. Figure 2-41.

Figure 2-41

6.Using a Phillips screwdriver, remove the 2 screws securing the gas valve to the bracket and remove gas valve from unit. Figure 2-42.

7.Remove the fittings from the gas valve and install in new gas valve.

Figure 2-42

8. Install the new gas valve in reverse order.

2-16. BLOWER MOTOR The blower motor assembly induces the draft for the burners. If the

REPLACEMENT blower motor fails, the air switch will fail to close, causing an “E-20B” error code in the display.

1.

Remove electrical power supplied to the unit.

 

To avoid electrical shock or property damage, move the

 

power switch to OFF and disconnect main circuit

 

breaker, or unplug cord at wall receptacle.

2.

Remove screws securing the rear cover to the unit.

Figure 2-43

Figure 2-43.

106

2-15

Page 15
Image 15
Henny Penny 342 manual Remove screws securing the rear cover to the unit