2-21. FILTER PUMP AND MOTOR REMOVAL (Continued)

Model OFE/OFG/OEA/OGA-341, 342

2-21. FILTER PUMP AND MOTOR REMOVAL (Continued)

7. Remove left side panel.

 

8.

Using 9/16” socket or wrenches, remove the bolts and nuts

 

 

securing the motor to the bracket and pull pump, motor, and

 

 

piping from unit. Figure 2-74.

Figure 2-74

 

 

2-22. AUTOLIFT

1.

Remove electrical power supplied to unit.

TRANSFORMER

 

 

REPLACEMENT

 

 

(if applicable)

 

 

 

 

To avoid electrical shock or property damage, move the

 

 

power switch to OFF and disconnect main circuit

 

 

breaker, or unplug cord at wall receptacle.

 

2.

Remove control panel.

 

3.

Label and remove wires from transformer. Figure 2-75.

Figure 2-75

4.Using 3/8” nut-driver or wrench, remove nuts securing transformer to panel and remove transformer from panel. Figure 2-76.

5.Install new transformer in reverse order.

Figure 2-76