MOTOR REMOVAL

Model OFE/OFG/OEA/OGA-341, 342

2-21. FILTER PUMP AND 1. Remove electrical power supplied to unit.

MOTOR REMOVAL

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Open the door (left door on 2 well units), and remove the 2 screws securing the switch box cover and pull filter motor wires from filter switch. Figure 2-70.

Figure 2-70

3.Remove the 2 screws securing the switch box to the frame. Figure 2-71

Figure 2-71

4.Loosen screws on conduit connector and pull conduit from the connector. Figure 2-72.

5.Disconnect filter union to filter in drain pan.

Figure 2-72

6.Using a pipe wrench, disconnect the outlet pipe to frypot. Figure 2-73.

Figure 2-73